Ypsomed mylife Loop (CamAPS FX on YpsoPump)
Ypsomed (with CamDiab and Dexcom/Abbott)
What it is
Ypsomed's commercial AID bundle: the tubed YpsoPump driven by CamDiab's adaptive CamAPS FX algorithm app, paired with a Dexcom or FreeStyle Libre sensor. From the user's perspective it is the same self-learning hybrid closed loop as CamAPS FX, sold as one integrated, phone-controlled package across the UK and EU.
Editorial review: .
Most recent recorded citation date: 2026-09-01. Only explicit date metadata is included; an undated citation may be newer. This does not mean every claim was reviewed on that date.
Trial status, labels and access can change between reviews. How we review the evidence · How to read the evidence
Evidence behind this assessment
Key evidence notes. Study results, product eligibility and access answer different questions.
- Who was studied?
- Study populations and analysis groups vary. Product age limits alone do not describe who was studied.
- Benefit or performance
- Time in range: Achieved real-world TIR of 69.6% (median, IQR 61.3-77.2) across 35,714 T1D users in 19 countries (Boughton et al., Metabologia 2026) is the most representative figure; a smaller 1,805-user real-world analysis reported a higher 72.6% ± 11.5%. By age, real-world TIR spans ~62.5% (young adults 18-22y) to ~76.1% (≥65y). Weighting toward the large, broad, multi-age cohort at ~70% places CamAPS FX at 74 on the achieved-TIR scale calibrated to the MiniMed 780G anchor (~76% = 80) — genuinely below the 780G anchor, kept conservative because the dominant dataset sits at ~70% rather than the smaller cohort's ~73%.[1]
- Important harms and treatment burden
- Read the safety discussion and original sources. A missing summary does not establish safety.
- Approval and country access
- Country-specific approval and access are not summarized in this record.Approval, trial recruitment, local supply and funding are separate. Check the cited label or access source.
- Follow-up and remaining uncertainty
- Read the full discussion and original sources for follow-up duration and study limitations.
This record cites company or conference reports. Those sources may describe interim findings; their source type is shown in the source list.
Editorial score: calculation and evidence
A weighted editorial judgment on a 0–100 scale, not a probability of success or a measured treatment effect. Higher criterion scores mean more favorable assessments.
Default calculation: 74 × 20 + 76 × 20 + 70 × 10 + 74 × 5 + 73 × 5 + 71 × 5 + 78 × 5 + 54 × 10 + 54 × 20 = 6800; divide by total weight 100. Unrounded weighted result: 68.
Achieved real-world TIR of 69.6% (median, IQR 61.3-77.2) across 35,714 T1D users in 19 countries (Boughton et al., Metabologia 2026) is the most representative figure; a smaller 1,805-user real-world analysis reported a higher 72.6% ± 11.5%. By age, real-world TIR spans ~62.5% (young adults 18-22y) to ~76.1% (≥65y). Weighting toward the large, broad, multi-age cohort at ~70% places CamAPS FX at 74 on the achieved-TIR scale calibrated to the MiniMed 780G anchor (~76% = 80) — genuinely below the 780G anchor, kept conservative because the dominant dataset sits at ~70% rather than the smaller cohort's ~73%.[1]
Achieved real-world time-below-70 mg/dL (<3.9 mmol/L) was 2.5% (median, IQR 1.4-3.9) in the 35,714-user cohort and 2.3% (IQR 1.3-3.6) in the 1,805-user cohort, staying <4% across every age group. A TBR of ~2.3-2.5% maps to the 76-78 band (the calibration places ~2-2.5% at 76-78, ~3% at 72-74); CamAPS FX's well-controlled hypoglycemia at scale supports 76.[1]
Self-learning MPC algorithm runs ~95% in closed-loop and adapts continuously; on this bundle, simplified meal announcement was non-inferior to full carb counting, but meals are still announced (hybrid).
Achieved GMI was 7.1% ± 0.5% (mean glucose 8.7 mmol/L) in the 35,714-user real-world cohort and 6.9% (mean glucose 8.4 mmol/L) in the 1,805-user cohort. A GMI near 7.1% reflects solid but not class-leading average-glucose control, consistent with the ~70% achieved TIR; scored 74 to align with the time-in-range anchor.[1]
Glycemic variability is not reported as a coefficient of variation in the primary real-world dataset, but the consistent TBR (~2.5%) alongside a ~70% TIR and GMI 7.1% across a 35,714-user, all-ages cohort indicates good day-to-day stability without exceptional tightening. Scored 73, slightly below the TIR anchor to reflect the absence of a directly reported low-CV figure and the conservative read of the larger cohort.[1]
Built-in Ease-off and Boost modes give user-triggered exercise-handling options.
Inherits CamAPS FX's adjustability for a commercial product: Ease-off/Boost modes in an app-based model.
Available across the UK and the EU, with availability expanded to Australia; sensor choice varies by country.
Runs on the small, light tubed YpsoPump — discreet for a tubed system, but with tubing and a separate body.
AID default: 50% glucose outcomes and low-glucose protection, 40% daily experience, 10% access and cost. Freedom includes tubing, wearability, water-use limits and controller requirements. These are editorial priorities; studies and device generations differ. Check each scorecard for its evidence and limits.
The full picture
Ypsomed mylife Loop is the commercial bundle that packages the CamAPS FX algorithm onto Ypsomed's hardware. It is, from a user's day-to-day standpoint, the same self-learning hybrid closed loop as CamAPS FX — we list it as a distinct commercial system because the components, regulatory footprint and access differ from a generic "CamAPS deployment."
Components. Three pieces work as one system: the tubed mylife YpsoPump (a small 83 g pump using a 160-unit / 1.6 mL cartridge of rapid-acting analog),8 the CamAPS FX app (CamDiab's adaptive model-predictive-control algorithm, the "brain"),9 and a continuous glucose sensor — Dexcom G7 or Abbott FreeStyle Libre 3/3 Plus.10 The whole loop is driven and bolused from the user's smartphone.11
Pivotal trial outcomes. The CamAPS FX algorithm's strongest evidence is a multicenter randomized crossover trial in 74 very young children (ages 1-7). Over two 16-week periods, the closed loop raised time-in-range (70-180 mg/dL) by 8.7 percentage points versus a sensor-augmented pump, lowered mean glucose by 12.3 mg/dL and HbA1c by 0.4 points, and did not increase time in hypoglycemia; the system ran in closed-loop mode ~95% of the time.12 A trial run on this exact bundle — YpsoPump + Dexcom G6 + CamAPS FX ("mylife CamAPS FX") in youth and young adults — reported ~70% time-in-range with only ~1.8% time below 3.9 mmol/L.13
Automation level. This is a hybrid loop: meals are still announced. But that same YpsoPump bundle trial showed simplified meal announcement (rough meal sizes instead of exact carb counting) was non-inferior to full carbohydrate counting for time-in-range — a meaningful reduction in daily burden.13 The algorithm continuously re-learns the individual's insulin needs.9
Exercise modes. Two built-in activity functions: Ease-off and Boost.11
Ages & indications. The algorithm is licensed for type 1 diabetes from age 1 and up (depending on the sensor) and is the only loop algorithm specifically indicated for pregnancy — reflecting its dedicated very-young-children and pregnancy trial programs.1014 Caregivers of very young children using it reported less fear of hypoglycemia and better well-being.15
Access. It is available across the UK and much of the EU, with availability expanded to additional countries including Australia; Italy joined the rollout schedule in October 2026.10
What's coming. Sensor support keeps widening (Dexcom G7 and FreeStyle Libre 3/3 Plus are now in scope),10 and full iOS support removed the previous Android-only constraint.10 Research continues into reducing meal burden further (the simplified-announcement work)13 and into the algorithm with faster insulins;16 the persistent ceiling, as for all hybrid loops, remains the speed of injected insulin and the need to announce meals at all.
Fully closed-loop option. CamAPS Liberty launched on 1 September 2026 in Germany, Austria and Switzerland for eligible myLoop users. This optional CamAPS FX mode removes routine meal boluses and carb counting for people with T1D aged 13+, and excludes pregnancy. The established hybrid-mode outcomes above should not be read as Liberty outcomes.17
CamAPS software safety updates. CamDiab’s notices retire affected Android app versions below 1.4(192) from 31 August 2026 for cybersecurity reasons. Pump, country, phone and sensor determine the applicable app build. Its September notices also advise checking CGM compatibility before an operating-system update. Use the manufacturer’s current notification and compatibility instructions for the exact configuration.18
What's next for this
- →Widening sensor support (Dexcom G7 and FreeStyle Libre 3/3 Plus now in scope)
- →Full iOS support removing the previous Android-only constraint · 2025
- →Research into reducing meal burden further (simplified announcement) and the algorithm with faster insulins
- →Broader CamAPS Liberty fully closed-loop rollout after the September launch in Germany, Austria and Switzerland · Italy targeted 28 October 2026
Sources
- [1]Real-world evidence on the CamAPS FX hybrid closed-loop system in people living with type 1 diabetes · Peer-reviewed study · 2026-01-01
- [2]Real-World Evidence Analysis of a Hybrid Closed-Loop System (CamAPS FX, 1,805 users / 15 countries) · Peer-reviewed study · 2023-01-01
- [3]AiDAPT: Closed-Loop Insulin Delivery in Pregnant Women with Type 1 Diabetes (NEJM) · Peer-reviewed study · 2023-01-01
- [4]Long-term assessment of the NHS hybrid closed-loop real-world study in children and young people with type 1 diabetes (incl. CamAPS FX) · Peer-reviewed study · 2024-01-01
- [5]CamAPS Liberty commercial launch, 1 September 2026 · Manufacturer · 2026-09-01
- [6]CamAPS Liberty indication and mode restrictions · Manufacturer
- [7]CamDiab app compatibility and version retirement notices · Manufacturer
- [8]
Ypsomed/mylife Diabetescare. mylife YpsoPump insulin pump — specifications (1.6 mL/160 U cartridge; 83 g). mylife Diabetescare (2025). https://www.mylife-diabetescare.com/en/products/infusion-systems/mylife-ypsopump-insulin-pump.html
- [9]
Laesser CI, et al. Simplified meal announcement study (SMASH) using hybrid closed-loop insulin delivery — describes the adaptive CamAPS FX algorithm. Diabetologia (2025). https://pubmed.ncbi.nlm.nih.gov/39560745/
- [10]
Ypsomed. Ypsomed and CamDiab expand availability of mylife CamAPS FX on iOS (sensors, ages, pregnancy indication, country rollout). Ypsomed press release (10 June 2025). https://www.ypsomed.com/en/news-insights/news/press-releases/news-reader-detail-page/ypsomed-and-camdiab-expand-availability-of-mylife-camaps-fx-on-ios
- [11]
Ypsomed/mylife Diabetescare. YpsoPump with mylife Loop — smartphone control, Ease-off and Boost activity functions. mylife Diabetescare (2025). https://www.mylife-diabetescare.com/en/mylife-loop.html
- [12]
Ware J, et al. Randomized Trial of Closed-Loop Control in Very Young Children with Type 1 Diabetes (CamAPS FX; TIR +8.7 pp, mean glucose −12.3 mg/dL, HbA1c −0.4 pp, no rise in hypoglycemia). N Engl J Med 386:209-219 (2022). https://doi.org/10.1056/NEJMoa2111673
- [13]
Laesser CI, et al. SMASH crossover trial on mylife CamAPS FX (YpsoPump, Dexcom G6): simplified meal announcement non-inferior to carb counting; TIR 69.9% vs 70.7%, time <3.9 mmol/L ~1.8%. Diabetologia 68(2):295-307 (2025). https://doi.org/10.1007/s00125-024-06319-w
- [14]
Lee TTM, et al. AiDAPT: automated insulin delivery among pregnant women with type 1 diabetes (CamAPS FX) — study protocol. BMC Pregnancy Childbirth 22:282 (2022). https://doi.org/10.1186/s12884-022-04543-z
- [15]
de Beaufort C, et al. Cambridge Hybrid Closed-Loop System in Very Young Children Reduces Caregivers' Fear of Hypoglycemia and Improves Well-Being. Diabetes Care 45(12):3050-3 (2022). https://doi.org/10.2337/dc22-0693
- [16]
Ware J, et al. Hybrid Closed-Loop with Faster Insulin Aspart vs Standard Insulin Aspart in Very Young Children (CamAPS FX; TIR ~64-65%). Diabetes Technol Ther 25(6):431-436 (2023). https://doi.org/10.1089/dia.2023.0042
- [17]
CamDiab launch announcement and mylife indication. https://camdiab.com/press-releases/liberty-launch; https://www.mylife-diabetescare.com/en/myloop/camaps-liberty
- [18]